YOUR CURRENT POSITION: Home > CABLE & WIRE > Offshore & Marine Cable

BFOU P5/P12 0.6/1KV (NEK606 )

Fire resistant offshore power 0,6/1kV LOW VOLTAGE 0,6/1 kV Based on: IEC 60092-353 / NEK TS 606

Applications

These P5 or P5/P12 BFOU 0.6/1KV NEK606 Water Blocked Offshore & Marine cables are fire resistant, flame retardant, low smoke,halogen free and mud resistant, used for control, power and lighting systems.Fire resistant offshore power 0,6/1kV cables. These fire resistant cables are specially de-signed to transmit electric power in the presence of fire, assuring electric supply to emer-gency circuits, like signaling lights, smoke extractors, acustic alarms, water pumps, etc. In case of fire, they do not emit toxic or corrosive gases, thereby protecting public health and avoiding any possible damage to electronic equipment. They are also heavy duty, mud resistant cables for Offshore applications.Halogen free, flame and fire non propagator. Excellent resistance to oils, abrasion, petrochemical fluids, moisture and salt water. Ba-sed on IEC 60092-353 and NEK TS 606. Suitable for fixed installations in vessels and oil rigs, assuring the highest level of safety, security and reliability.

Standards

IEC 60092
IEC 60332 
NEK 606 

Construction

Conductors: Tinned annealed stranded compacted copper to IEC 60228 class 2.
Insulation: Mica tape + Halogen free EPR/Mica tape + XLPE.
Filler: Water blocking fillers, if required.
Bedding: Halogen free compound, PETP wrapping tape will be applied over the bedding, if required.
Armour: Tinned copper wire braid, PETP wrapping tape will be applied over the braiding, if required.
Water Blocking Elements: Water blocking tape and strings for providing longitudinal water tightness.
Inner Sheath: Halogen free thermosetting compound, SHF2 (for TYPE P5). Halogen free, mud resistant thermosetting compound, SHF MUD (for TYPE P5/P12), coloured black.
Outer Sheath: Polyurethane for providing transversal water tightness, PE is optional,but can not meet low smoke standard.

Electrical Characteristics

NOMINAL CROSS SECTION AREA MM2 1.5 2.5 4 6 10 16 25 35 50
NOMINAL CONDUCTOR DIAMETER MM 1.6 2.1 2.6 3.2 4 5.1 6.5 7.4 8.7
MAXIMUM DC RESISTANT@20˚C O/KM 12.2 7.56 4.7 3.11 1.84 1.16 0.734 0.529 0.391
CONTINUOUS CURRENT RATING@45˚C1 CORE A 23 30 40 52 72 96 127 157 196
CONTINUOUS CURRENT RATING@45˚C2 CORE A 20 26 34 44 61 82 108 133 167
CONTINUOUS CURRENT RATING@45˚C3&4 CORE A 16 21 28 36 50 67 89 110 137
SHORT CIRCUIT CURRENT 1S A 210 360 570 860 1430 2290 3580 5010 7150
OPERATING VOLTAGE KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1
NOMINAL CROSS SECTION AREA MM2 70 95 120 150 185 240 300 400 630
NOMINAL CONDUCTOR DIAMETER MM 10.3 12.2 13.8 15.1 17.0 19.6 21.9 24.6 32.5
MAXIMUM DC RESISTANT@20˚C O/KM 0.27 0.195 0.154 0.126 0.1 0.0762 0.0607 0.0475 0.0286
CONTINUOUS CURRENT RATING@45˚C1 CORE A 242 293 339 389 444 522 601 690 890
CONTINUOUS CURRENT RATING@45˚C2 CORE A 206 249 288 331 444 444 511 587 757
CONTINUOUS CURRENT RATING@45˚C3&4 CORE A 169 205 237 272 311 365 421 483 623
SHORT CIRCUIT CURRENT 1S A 10020 13590 17170 21460 26470 34340 42930 57230 90140
OPERATING VOLTAGE KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1
Note: For more than 4-cores, the current ratings may be calculated from the following formula (IN=I1/ 3v N ), I1= Current rating for 1-core, N = Number of cores.
Ambient Temperature Correction Factors
AMBIENT TEMPERATURE CORRECTION FACTORS 35 40 45 50 55 60 65 70 75 80
RATING FACTOR 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Mechanical and Thermal Properties

Bending Radius : 8×OD (during installation); 6×OD (fixed installed).
Temperature Range : -20˚C ~ +90˚C.

Dimensions and Weight

CONSTRUCTION NO. OF CORES×CROSS SECTION (MM2) NOMINAL INSULATION THICKNESS MM NOMINAL BEDDING THICKNESS MM NOMINAL INNER SHEATH THICKNESS MM NOMINAL OUTER SHEATH THICKNESS MM    
NOMINAL OVERALL DIAMETER MM NOMINAL WEIGHT KG/KM
1×1.5 1 1.1 1.1 1 11.3±2 152
1×2.5 1 1.1 1.1 1 11.7±2 168
1×4 1 1.1 1.1 1 12.4±2 231
1×6 1 1.1 1.1 1 12.9±2 263
1×10 1 1.1 1.2 1 14.7±2 326
1×16 1 1.1 1.2 1 15.9±2 410
1×25 1.2 1.1 1.3 1.2 18.7±2 614
1×35 1.2 1.1 1.3 1.2 19.6±2 725
1×50 1.4 1.1 1.4 1.2 21.4±2 935
1×70 1.4 1.1 1.4 1.2 23.0±2 1166
1×95 1.6 1.1 1.5 1.4 25.9±2 1512
1×120 1.6 1.2 1.6 1.4 27.8±2 1822
1×150 1.8 1.2 1.7 1.4 29.8±2 2163
1×185 2 1.2 1.7 1.4 32.2±2 2672
1×240 2.2 1.2 1.8 1.6 35.8±2 3329
1×300 2.4 1.2 1.9 1.6 38.5±2 4106
1×400 2.4 1.4 2.1 1.6 44.2±2 5355
1×630 2.8 1.4 2.3 1.6 51.7±2 8043
2×1.5 1 1.1 1.2 1 16.2±2 326
2×2.5 1 1.1 1.3 1 17.1±2 378
2×4 1 1.1 1.3 1 18.6±2 494
2×6 1 1.1 1.4 1 19.9±2 583
2×10 1 1.1 1.4 1 21.9±2 740
2×16 1 1.1 1.5 1 24.5±2 1034
2×25 1.2 1.2 1.6 1.2 28.8±2 1428
2×35 1.2 1.2 1.7 1.2 30.8±2 1701
2×50 1.4 1.2 1.9 1.2 34.8±2 2405
2×70 1.4 1.2 2.1 1.2 40.4±2 3423
2×95 1.6 1.2 2.3 1.4 44.4±2 4106
2×120 1.6 1.4 2.4 1.4 48.1±2 4946
2×150 1.8 1.4 2.6 1.4 52.5±2 5954
2×185 2 1.4 2.7 1.4 57.1±2 7182
2×240 2.2 1.6 3 1.6 64.7±2 9230
2×300 2.4 1.6 3.2 1.6 71.0±2 11162
3×1.5 1 1.1 1.3 1 16.8±2 362
3×2.5 1 1.1 1.3 1 18.2±2 467
3×4 1 1.1 1.3 1 19.4±2 557
3×6 1 1.1 1.4 1 20.7±2 667
3×10 1 1.1 1.5 1 23.1±2 872
3×16 1 1.1 1.5 1 25.7±2 1218
3×25 1.2 1.2 1.7 1.2 30.5±2 1722
3×35 1.2 1.2 1.8 1.2 32.6±2 2079
3×50 1.4 1.2 2 1.2 36.7±2 2888
3×70 1.4 1.2 2.2 1.2 41.4±2 3859
3×95 1.6 1.4 2.4 1.4 47.5±2 5203
3×120 1.6 1.4 2.5 1.4 51.1±2 6337
3×150 1.8 1.4 2.7 1.4 56.0±2 7723
3×185 2 1.6 2.9 1.4 62.3±2 9476
3×240 2.2 1.6 3.2 1.6 69.7±2 12170
3×300 2.4 1.8 3.4 1.6 75.8±2 14427
4×1.5 1 1.1 1.3 1 18.4±2 420
4×2.5 1 1.1 1.3 1 19.3±2 530
4×4 1 1.1 1.4 1 20.8±2 651
4×6 1 1.1 1.4 1 22.1±2 788
4×10 1 1.1 1.5 1 24.7±2 1034
4×16 1 1.2 1.6 1 27.9±2 1470
4×25 1.2 1.2 1.8 1.2 33.1±2 2095
4×35 1.2 1.2 1.9 1.2 35.5±2 2562
4×50 1.4 1.4 2 1.2 40.6±2 3602
4×70 1.4 1.4 2.2 1.2 45.1±2 4830
4×95 1.6 1.6 2.4 1.4 52.2±2 6442
4×120 1.6 1.6 2.5 1.4 56.4±2 7891
4×150 1.8 1.6 2.9 1.4 61.8±2 9461
4×185 2 1.6 3.1 1.4 67.5±2 11550
4×240 2.2 1.8 3.4 1.6 76.3±2 14868
4×300 2.4 1.8 3.7 1.6 83.9±2 18428
5×1.5 1 1.1 1.4 1 19.7±2 536
6×1.5 1 1.1 1.4 1 21.0±2 572
7×1.5 1 1.1 1.4 1 21.0±2 620
8×1.5 1 1.1 1.5 1 23.8±2 751
9×1.5 1 1.1 1.6 1 25.3±2 756
10×1.5 1 1.1 1.6 1 25.6±2 830
12×1.5 1 1.2 1.6 1 26.3±2 924
14×1.5 1 1.2 1.7 1 27.5±2 1013
16×1.5 1 1.2 1.7 1 28.7±2 1087
19×1.5 1 1.2 1.7 1 29.4±2 1244
20×1.5 1 1.2 1.8 1 31.5±2 1323
23×1.5 1 1.2 1.9 1 33.8±2 1507
24×1.5 1 1.2 2 1 35.2±2 1586
27×1.5 1 1.2 2 1 35.9±2 1696
30×1.5 1 1.2 2 1 36.9±2 1822
32×1.5 1 1.4 2 1 37.5±2 1890
33×1.5 1 1.4 2 1 38.7±2 2037
37×1.5 1 1.4 2 1 40.0±2 2195
44×1.5 1 1.4 2.3 1 44.6±2 2583
5×2.5 1 1.1 1.4 1 20.8±2 625
6×2.5 1 1.1 1.4 1 22.4±2 683
7×2.5 1 1.1 1.4 1 22.4±2 735
8×2.5 1 1.1 1.5 1 25.5±2 830
9×2.5 1 1.1 1.6 1 27.1±2 903
10×2.5 1 1.1 1.6 1 27.4±2 1003
12×2.5 1 1.2 1.6 1 28.1±2 1097
14×2.5 1 1.2 1.7 1 29.3±2 1218
16×2.5 1 1.2 1.8 1 30.8±2 1328
19×2.5 1 1.2 1.8 1 31.6±2 1517
20×2.5 1 1.2 1.9 1 33.8±2 1622
23×2.5 1 1.4 2 1 36.7±2 1895
24×2.5 1 1.4 2 1 37.8±2 1943
27×2.5 1 1.4 2 1 37.4±2 2069
30×2.5 1 1.4 2.1 1 40.1±2 2347
33×2.5 1 1.4 2.2 1 41.6±2 2510
37×2.5 1 1.4 2.3 1 43.2±2 2741
44×2.5 1 1.4 2.4 1 48.2±2 3229
Note: For XLPE insulated cable, a thinner insulation thickness is applied.
 

Contact Us, Now.
24-hour service hotline
Contact online customer service
Add: Technology Building, Tongbai Road, Zhongyuan District, Zhengzhou, Henan, China.
Related products
RFOU(i) S2/S6 250V NEK606
MV RFOU/TFOU P4/P11 Cable 8.7/15KV(NEK606)  
MV RFOU P19/P21 12/20KV (NEK606) 
Offshore & Marine Shielded Pairs Instrumentation Cables